Rated voltage |
100 kVDC |
160 kvDC |
250 kvDC |
Nominal outside diameter |
20 mm |
29 mm |
36 mm |
Coverage shielding braid |
>95% |
>95% |
>80% |
Conductor resistance bare conductor @ 20° C |
6.6 mΩ/m |
6.6 mΩ/m |
6.6 mΩ/m |
Conductor resistance red & white cond. @ 20° C |
9.5 mΩ/m |
11.4 mΩ/m |
11.4 mΩ/m |
Minimum bending radius (dynamic) |
80 mm |
120 mm |
148 mm |
Insulation resistance (wires to shield) |
≥5x1012 Ω.m |
≥1x1012 Ω.m |
≥1x1012 Ω.m |
Capacitance (wires to shild) |
136 pF/m |
126 pF/m |
107 pF/m |
Max. operationg temperature |
+70° C |
+70° C |
+70° C |
|
|
|
|

|
R10 |
R24 |
R24 RA |
R28 |
R28 RA |
R30 |
R30 RA |
U3/100 cable |
100 kV |
100 kV |
100 kV |
|
|
|
|
N3/160 cable |
|
160 kV |
160 kV |
160 kV |
160 kV |
160 kV |
160 kV |
P3/250 cable |
|
225 kV |
225 kV |
225 kV |
225 kV |
225 kV |
225 kV |
Within the high voltage system the part with the lowest specified high voltage rating defines the maximum allowed voltage. Special cables, terminals and flanges are available on request. Please contact us.
|
Cable |
Plug |
Plug |
Length |
Cable |
N3/160 |
R24 |
R24 RA |
5m |
Flange |
10001756 |
|
|
|

Example: 160 kV cable with straight and rectangular connector, lenght 5m with a flange for MXR-160.

Datasheet Cables, Flanges, Quick Locks (0.1 MB)
|